Siemens MC0816B1400RLTM 400 Amp 8 Space 16 Circuit Levery Bypass Meter-Load Center Combination Main Breaker with Feed Thru Lugs and Ringless Cover

Siemens MC0816B1400RLTM 400 Amp 8 Space 16 Circuit Levery Bypass Meter-Load Center Combination Main Breaker with Feed Thru Lugs and Ringless Cover

The MC0816B1400RLTM comes with a class 320 lever bypass meter socket. The load center portion is provided with one 200A main breaker and an 8 space/16 circuit interior with feed thru lugs. There is also a provision for an additional main breaker rated up to 200 Amps. The construction allows for the 8/16 circuits inside the panel to feed exterior loads while also providing the ability to feed up to 2 more load centers from this panel. The 2nd main breaker provision will accept the QNR type (150, 175, or 200 Amp) and QP type double pole breakers (60, 70, 80, 90, 100, or 125 Amp). The enclosure is rated NEMA Type 3R (outdoor use), confirms to UL standard 50 and is fabricated using Galvanized steel with a baked on polyester powder coating. The panel is rated for overhead or underground feed applications. For overhead feed, use the Electric enter "HD" class of hubs (EC56854, EC56855, EC56856, EC56857, or EC56858).

  • UPC: 783643484146
  • ASIN: B008KM9VIC
  • Brand: Siemens
  • Manufacturer: Siemens

AC Current Voltage Amperage Power Energy Panel Meter LCD Digital Display Ammeter Voltmeter Multimeter with Split Core Current Transformer CT AC 80-260V 100A (AC 100A Meter(Split Core Transformer))

AC Current Voltage Amperage Power Energy Panel Meter LCD Digital Display Ammeter Voltmeter Multimeter with Split Core Current Transformer CT AC 80-260V 100A (AC 100A Meter(Split Core Transformer))

A.Main Function 1. Electrical parameter measurement function (voltage, current, active power, energy, frequency, power factor) 2. Overload alarm function (over power alarm threshold, backlight and power flashing to alarm). 3. Power alarm threshold preset function (can set power alarm threshold). 4. The energy can be reset use the key. 5. Store data when power off. 6. Large-screen LCD 7. Backlight function. B. Appearance and Key function Display interface is large-screen LCD, it can display six parameters at the same time. 1. Power: test range: 0~22000W, Starting measure power: 0.5W 2. Energy: test range: 0~999kWh 3. Voltage: test range: 80~260V 4. Current: test range: 0~100A,Starting measure current: 0.02A 5. Frequency: test range: 45~65Hz 6. Power factor: test range: 0~1PF C.Specification parameters 1. Working voltage: 80 ~ 260VAC 2. Test voltage: 80 ~ 260VAC 3. Rated power: 100A/22000W 4. Operating frequency: 45-65Hz 5. Measurement accuracy: 1.0 grade  

  • UPC: 703931915688
  • ASIN: B07JB9B2QL
  • Brand: MORNING GROUP
  • Size: AC 100A Meter(Split Core Transformer)
  • Manufacturer: Wenzhou Morning Electronics Co., LTD

DROK AC 500V 200A Voltmeter Ammeter Display Panel

DROK AC 500V 200A Voltmeter Ammeter Display Panel

Description: Display voltage and current on the same screen with different color (red for voltage, green for current). Green terminal should be connected to the CT; the red line and black line should be connected to the circuit being tested. Wrong connection will burn the meter. Note: 1. Please connect all components in your circuit at first, and connecting the 220V power supply must be the final step. Do not touch the circuit and any parts on the back of this product after connecting with power supply to avoid electric shock. 2. Not suitable for high frequency electronic speed control, non city electric sine wave frequency or other occasions with high frequency components, because the product adopts the theory of capacitor step-down. Parameters: Voltage measuring range: AC130-500V Current measurement range: AC0.0-200A Resolution: 1V 1A CT inner hole: 25mm Measurement accuracy: 1% + 2 digits Display: 0.39 inch LED digital tube display Measuring speed: about 2times per second Exterior dimension: 70 * 40 * 30 mm Installation dimension: 68 * 38mm The power supply line, measuring length: about 150mm Transformer lead length: about 100mm Operating temperature: -10 ~ +50 Working humidity: 10 ~ 80% (no condensation) Working pressure: 80 ~ 106kPa Sun exposure: no direct exposure Package includes: 1x Digital Volt Ampere Meter + 1x Current Transfer (CT)

  • ASIN: B01M8LCWNW
  • Brand: DROK
  • Size: AC 130-500V 200A LED Volt Amp Meter
  • Manufacturer: DROK

FidgetGear DC Analog Meter Panel Voltmeter Voltage Meter DH-670 0-20V Gauge

FidgetGear DC Analog Meter Panel Voltmeter Voltage Meter DH-670 0-20V Gauge

Product Name : Analog Ammeter Model No. : DH-670 Measuring Current Range : DC 0-20V Accuracy : Class 2.5 Meter Size : 7.1 x 6.1 x 1cm Thread Size : 4x 8.5mm Material : Plastic, Electronic Components Package Con

  • ASIN: B07MTG2KNY
  • Brand: FidgetGear
  • Manufacturer: FidgetGear

Square D by Schneider Electric RC816F200C Homeline 200-Amp Main Breaker 8-Space 16-Circuit Outdoor Overhead/Underground CSED

Square D by Schneider Electric RC816F200C Homeline 200-Amp Main Breaker 8-Space 16-Circuit Outdoor Overhead/Underground CSED

The Square D 200 Amp 8-Space 16-Circuit Combination Meter Socket and Main Breaker Load Center is suitable for use as a combination service entrance device (CSED). This unit is ANSI certified and UL listed with a maximum 22,000 AIR. The ringless unit is intended for use as a combination meter socket and main breaker load center. It is suitable for overhead or underground service applications. The unit has feed-through lugs. This CSED is built with a plated, aluminum bus bar that is tested and listed only for Homeline circuit breakers. Homeline CSEDs are designed for the value-minded contractors, remodelers, builders and homeowners. Homeline CSEDs are engineered for fast installation and wire savings.

  • UPC: 785901863922
  • ASIN: B004TTE1W6
  • Brand: Square D by Schneider Electric
  • Size: Packs
  • Manufacturer: Square D by Schneider Electric

Siemens MM0404L1400RLM 400-Amp Levery Bypass Meter Main Combination with and Ringless Cover

Siemens MM0404L1400RLM 400-Amp Levery Bypass Meter Main Combination with and Ringless Cover

The MM0404L1400RLM comes with a class 320 lever bypass meter socket and provisions for 2 main breakers up to 200 Amp each. The breakers are not included. This panel allows the user to feed up to two 200 Amp rated load centers. The panel will accept the QNR (150, 175, or 200 Amp) and QP type double pole breakers (60, 70, 80, 90, 100, or 125 Amp). The enclosure is rated NEMA Type 3R (outdoor use), confirms to UL standard 50 and is fabricated using Galvanized steel with a baked on polyester powder coating. The panel is rated for overhead or underground feed applications. For overhead feed, use the Electric enter "HD" class of hubs (EC56854, EC56855, EC56856, EC56857, or EC56858).

  • UPC: 783643481435
  • ASIN: B008KMFNG6
  • Brand: SIEMENS
  • Manufacturer: Siemens

Akozon VU Meter 2 Pcs VU Panel Meter Warm Back Light Recording + Audio Level Amp with Driver Board

Akozon VU Meter 2 Pcs VU Panel Meter Warm Back Light Recording + Audio Level Amp with Driver Board

In the backlight brightness to meet the requirements under the conditions, lower operating voltage, can significantly prolong life. Need to use current limiting resistor in series 100Ω to 200Ω, reduce the impact on the filament boot Specifications: Voltage 500MV Header DC resistance: 652Ω Operating voltage: 6 ~ 12V AC or DC Material: Plastic + metal Driver board: 6.8cm x 5.5cm/2.67 x 2.16inch VU meter: 3.4cm x 3.4cm/1.33 x 1.33inch Weight: 90g Packing Include: 2 x 500μA VU Meter 1 x AC12V driver

  • UPC: 763741896218
  • ASIN: B07FZ3T4PB
  • Brand: Akozon
  • Manufacturer: Akozon

Square D by Schneider Electric SC2040M200C Home line Square D All-In-One Combination Load Center, 120/240 Vac, 200 A

Square D by Schneider Electric SC2040M200C Home line Square D All-In-One Combination Load Center, 120/240 Vac, 200 A

Home line Square D Load Center, All-in-One, Combination, 120/240 VAC, 200 A, 1 Phases, 3-Wire Wiring, 10 kA Interrupt, 20 Spaces, 40 Circuits, 1/0 - 12 AWG AL/CU Cable, Overhead/Underground Feed, Ring Cover, Aluminum Buss Bar, Surface Mounting, NEMA 3R Outdoor/Rainproof Enclosure, Includes: (1) SC200F Kit, ANSI Specified, UL Listed, 1 Gang. The Square D 200 Amp 20-Space 40-Circuit Combination Meter Socket and Main Breaker Load Center is suitable for use as a combination service entrance device (CSED). This unit is ANSI certified and UL listed with a maximum 10,000 AIR. The ring type unit is intended for use as a combination meter socket and main breaker load center. It is suitable for overhead or underground service applications. Meets EUSERC Specifications. Surface mount, convertible to semi-flush with SC200F kit. This CSED is built with a plated, aluminum bus bar that is tested and listed only for Home line circuit breakers. Home line CSEDs are designed for the value-minded contractors, remodelers, builders and homeowners. Home line CSEDs are engineered for fast installation and wire savings.

  • UPC: 785901859093
  • ASIN: B000KKNMY6
  • Brand: Square D by Schneider Electric
  • Manufacturer: Square D by Schneider Electric

DROK 090077 Small Little DC Digital Voltmeter 2-Wire 0.56" DC 3-30V Red Bright LED Car Motor Panel Mount Meter 5V 12V 24V 27V Solar Battery Volt Accurate Power Monitor Gauge

DROK 090077 Small Little DC Digital Voltmeter 2-Wire 0.56" DC 3-30V Red Bright LED Car Motor Panel Mount Meter 5V 12V 24V 27V Solar Battery Volt Accurate Power Monitor Gauge

Parameters: Dimensions: 48mm x 29mm x 22mm Cutting size : 46mm x 27mm Measure voltage: DC 3-30V (two wires Access) Input Polarity: DC voltage Measurement precision:0.01V(3-10V); 0.1V (10-30V) Display: Three 0.56" digital LED Tube Display Color: Green Refresh rate: about 500mS / times Operating temperature: -10°c to 65°c Features: 1. Safe to use: With reversed connection protection, this item will not burn even when connected reversely , but its screen will display nothing 2. Easy to connect wires: It has only two wires(the red and the black),simply connect the red to positive and black to the negative 3. High accuracy: Its decimal point will automatically move, meaning there is one digit after the decimal point when the voltage is higher than 10V, and 2 digits after the decimal point when the voltage lower than 10V,which allows more accurate display 4. Good-quality material: Its strong plastic case prevents it from easily damaged by outer force.;more, high-quality LED is adapted in this item, which is bright even in dim light Wiring connection: Red wire: connect to input positive pole Black wire: connect to input negative pole Potentiometer usage: You should adjust the potentiometer when your input voltage is about 20V. Please use a screwdriver to adjust the potentiometer to meet your requirements. Applications: You can use this meter to monitor voltage or battery of cars, vehicles, sailboat, RV, truck, race car, automotive, etc. Package Includes: 1x Digital LED Voltmeter

  • UPC: 619397027684
  • ASIN: B00C2NQ83Q
  • Brand: DROK
  • Size: Volt Meter
  • Manufacturer: DROK

Siemens MC0816B1200RCT Speed fax Load Center, 120/240 Vac, 200 A, Mbk200 Main Breaker

Siemens MC0816B1200RCT Speed fax Load Center, 120/240 Vac, 200 A, Mbk200 Main Breaker

Siemens meter load center combinations feature a 200 Amp rated meter socket combined with a 200 Amp main breaker service disconnect, available branch circuits, and feed thru lugs. The extra circuits allow for outdoor circuits to be wired directly from this panel, saving wire and installation time. Utility acceptace for all metering products varies, so check your local utility for acceptance before installing.

  • UPC: 783643510708
  • ASIN: B000KKK1OK
  • Brand: SIEMENS
  • Manufacturer: Siemens