Lg 2H00677S Room Air Conditioner Power Cord Genuine Original Equipment Manufacturer (OEM) Part

Lg 2H00677S Room Air Conditioner Power Cord Genuine Original Equipment Manufacturer (OEM) Part

Genuine Original Equipment Manufacturer (OEM) parts! This power cord (part number 2H00677S) is for room air conditioners. Unplug the room air conditioner before installing this part. Wear work gloves to protect your hands.

  • ASIN: B001PB06BQ
  • Brand: LG
  • Manufacturer: LG

PowerWell 45+5 MFD 45/5 uf 370 or 440 Volt Dual Run Round Capacitor PW-45/5/R for Condenser Straight Cool or Heat Pump Air Conditioner - Guaranteed to Last 5 Years

PowerWell 45+5 MFD 45/5 uf 370 or 440 Volt Dual Run Round Capacitor PW-45/5/R for Condenser Straight Cool or Heat Pump Air Conditioner - Guaranteed to Last 5 Years

A capacitor is an electric component that temporarily stores an electrical charge. A dual "run capacitor" supports two electric motors, such as in large air conditioner or heat pump units, with both a fan motor and a compressor motor. It saves space by combining two physical capacitors into one case. The dual capacitor has three terminals labeled "C", "FAN", and "HERM", which stand for the *C*ommon, Fan, and *HERM*etically sealed compressor. Dual capacitors come in a variety of sizes, depending on the capacitance (µF or MFD), such as 40 plus 5 µF, and also the voltage. A 440 volt capacitor can be used in place of a 370 volt, as it is build better, but the 370 can't be used in place of a 440 volt. It will work for a while and will fail prematurely, as exceeding the capacitor's rated voltage will cause the dielectric to break down and the capacitor to short out. Same as an electric wire- 600V rated wire is better than 300V one .The capacitance(µF or MFD) must be the same or stay within 10%+ or 5%- of its original value . Example: 50 µF cap can be substituted by 47.5 to 55 µF with the same or better voltage ratings capacitor . Round cylinder-shaped dual run capacitors are commonly used for air conditioning, to help in the starting of the compressor and the condenser fan motor.Round capacitor can be used to substitute oval shape one with the same MFD AND Volt specs You will ask "Why I need a Cap that is rated 440V in my A/C?" Answer: You need to realize that a motor is an inductive device. When the supply voltage is applied to the motor run winding, the voltage across the start winding will be increased to a higher voltage value. A motor acts like a transformer with the run winding acting as the primary and the start winding acting as the secondary. This is why the capacitor has a much higher voltage rating than the 230 being the supply voltage. If a Capacitor is not EIA-456-A approved means it is not approved for US market.

  • UPC: 714833366249
  • ASIN: B01NAZJYWA
  • Brand: PowerWell
  • Manufacturer: PowerWell

5304476768 Room Air Conditioner Power Cord Genuine Original Equipment Manufacturer (OEM) Part

5304476768 Room Air Conditioner Power Cord Genuine Original Equipment Manufacturer (OEM) Part

Genuine Original Equipment Manufacturer (OEM) parts! This power cord (part number 5304476768) is for room air conditioners. Unplug the room air conditioner before installing this part. Wear work gloves to protect your hands. For Frigidaire & Crosley.

  • ASIN: B0045RU9DC
  • Brand: FRIGIDAIRE
  • Manufacturer: Frigidaire

Genteq Capacitor Dual Run Round 35uF + 5uf MFD (micro Farad) 370 Volt VAC 97F9834 (replace old GE# Z97F9834) 35uF/5uF at 370 volts

Genteq Capacitor Dual Run Round 35uF + 5uf MFD (micro Farad) 370 Volt VAC 97F9834 (replace old GE# Z97F9834) 35uF/5uF at 370 volts

Genteq ( formerly GE Industrial ) is our most popular line of capacitors, and the choice of most OEMs. Genteq creates innovative, premium comfort and electrical components; their proven reputation for high quality, highly reliable products make this the preferred capacitor brand. Genteq Motor Run Capacitors replace / supersede old obsolete GE Industrial capacitors and are considered the most reliable capacitor available. Genteq is the choice of Most Major Manufacturers. Take Note: Many dimensions have changed due to engineering and changes in manufacturing...if your dimensions are critical , be sure and contact us for current dimensions. All dimensions subject to change without notice. Buy with Confidence from Airstar Supply your Premier Authorized Genteq Distributor!!

  • UPC: 610395592242
  • ASIN: B008OJRHJG
  • Brand: Genteq
  • Size: Original version
  • Manufacturer: Genteq

PowerWell 30 5 MFD uf 370 or 440 Volt Dual Run Round Capacitor PW-CAP-30/5/370-440R for Condenser Straight Cool or Heat Pump Air Conditioner

PowerWell 30 5 MFD uf 370 or 440 Volt Dual Run Round Capacitor PW-CAP-30/5/370-440R for Condenser Straight Cool or Heat Pump Air Conditioner

A capacitor is an electric component that temporarily stores an electrical charge. A dual "run capacitor" supports two electric motors, such as a fan motor and a compressor. Round dual run capacitors are used to start and run the unit more efficient. It saves space by combining two physical capacitors into one case. The dual capacitor has three terminals labeled "C", "FAN", and "HERM", which stand for the *C*ommon, Fan, and *HERM*etically sealed compressor.Dual capacitors come in a variety of sizes, depending on the capacitance (µF = MFD = micro farad), such as 60 plus 5 µF, and also the voltage. A 440 volt capacitor can be used in place of a 370 volt, as it is build better, but the 370 can't be used in place of a 440 volt. It will work for a while and will fail prematurely, as exceeding the capacitor's rated voltage will cause the dielectric to break down and the capacitor to short out. Same as an electric wire- 600V rated wire is better than 300V one .The capacitance(µF or MFD or micro farad) must be the same or stay within 10%+ or 5%- of its original value . Example: 30 µF cap can be substituted by 29 - 33 MFD with the same or better voltage ratings capacitor.If your fan is working but compressor not, or the capacitor is bulged on top most likely your capacitor is defective. Round capacitor can be used to substitute oval shape one with the same MFD AND Volt specs.You will ask "Why I need a Cap that is rated 440V in my A/C?"Answer: You need to realize that a motor is an inductive device. When the supply voltage is applied to the motor run winding, the voltage across the start winding will be increased to a higher voltage value. A motor acts like a transformer with the run winding acting as the primary and the start winding acting as the secondary. This is why the capacitor has a much higher voltage rating than the 230 being the supply voltage.If a Capacitor is not EIA-456-A approved means it is NOT approved for USA market.

  • UPC: 817506022579
  • ASIN: B0725VK8WQ
  • Manufacturer: PowerWell

OEM Haier Air Handler Power Control Board PCB for HB3600VD1M22, HB3600VD2M20, HB3600VD2M20T

OEM Haier Air Handler Power Control Board PCB for HB3600VD1M22, HB3600VD2M20, HB3600VD2M20T

This OEM Haier PCB Board is specifically for the following Air Handlers: HB3600VD1M22, HB3600VD2M20, HB3600VD2M20T Don't see your model number in the above list? Send us a message as we are happy to help!

  • ASIN: B07B6S1B6P
  • Brand: Haier
  • Manufacturer: Haier

45/5 uf MFD 440

45/5 uf MFD 440

Replaces / Supersedes: TITAN PRO TRCFD455 Motor Run Capacitor , C4455 , 27L889BX , 27L889 , CPT00656 , CPT0656 , CPT-0656 and old GE Industrial Capacitors with 45+5 x 440 VAC Rating Genteq ( formerly GE Industrial ) is our most popular line of capacitors, and the choice of most OEMs. Genteq creates innovative, premium comfort and electrical components; their proven reputation for high quality, highly reliable products make this the preferred capacitor brand. Specifications: All Capacitors are Individually Boxed , High-Grade Metallized Polypropylene Film (5 to 12 microns) , UL Approved & Patented Pressure Sensitive Interrupter (PSI) , Proven EIA-456 Compliant with 60,000 Hour Reliability , RoHS Compliant

  • UPC: 616469714435
  • ASIN: B00BHKRZ14
  • Brand: Genteq
  • Manufacturer: GE/Genteq

BANDO Toyota Tacoma April 1997 on through 2004 2.7L FOUR CYLINDER Alternator-Air Conditioner-Power Steering Belt Set(3 belts) BANDO 4PK870 5PK865 4PK1110

BANDO Toyota Tacoma April 1997 on through 2004 2.7L FOUR CYLINDER Alternator-Air Conditioner-Power Steering Belt Set(3 belts) BANDO 4PK870 5PK865 4PK1110

FITS; April 1997-2004 TOYOTA TACOMA 2.7 ENGINES FOUR CYLINDER ENGINES90080-91125-83, Power Steering Drive Belt 4pk111090916-02336, Alternator Water Pump Belt 5pk865 99364-20870-78, Drive Belt Air Conditioner 4PK870BANDO tacoma 1997-2002 Alternator-Air Conditioner-Power Steering Belt Set(3 belts)BANDO 4PK870 4PK1110 5pk865 BANDOBANDO TACOMA PARTS 1997BANDO TACOMA PARTS 1998 BANDO TACOMA PARTS 1999BANDO TACOMA PARTS 2000BANDO TACOMA PARTS 2001BANDO TACOMA PARTS 2002 COMPLETE DRIVE BELT SET: Alternator, Air Conditioner, and Power Steering for 1995 tacoma,1996 tacoma,1997 tacoma,1998 tacoma,1999 tacoma, 2000 tacoma, 2001 tacoma, 2002 tacoma,four cylinder 2.7 Bando has been manufacturing rubber products for over 100 years. Bando is the OEM suppliers to over 80 percentage of the top 10 cars sold in the U.S. (by volume). As an OEM belt manufacturer, the serpentine belts are precision ground two times to insure adherence to OEM specification. Belts produced from a mold process will not achieve the exact rib profiles that are required by OEM suppliers. Bando belts are made with EPDM rubber which adheres to OEM specification which is more heat resistant and long lasting. With 19 plants worldwide, Bando is the 3rd largest manufacturer of automotive drive belts in the world. Bando USA manufactures belts in Bowling Green, Kentucky. All Bando belts are produced to one premium set of standards with only OEM quality. Bando USA, with an ISO and QS9000 certified plant in Bowling Green, Kentucky has 16 additional plants located in 10 countries producing belts for local OEM. Automotive belts, serpentine, timing and V-belts from Bando manufactures belts for the leading automakers, supplying both OEM and aftermarket applications, all to the same exacting standards of quality.

  • ASIN: B06X9X51JC
  • Brand: TBK Timing Belt Kit
  • Manufacturer: BANDO

GE Genteq Capacitor Round 55/5 uf MFD 440 Volt 97F9839

GE Genteq Capacitor Round 55/5 uf MFD 440 Volt 97F9839

GE Genteq Capacitor round 55/5 uf MFD 440 volt 97F9839 (replaces old GE# 97Z9839BZ3, Z97F9839, & 97F9839BX, CPT00670, P2915554RS), 55 + 5 MFD at 440 volts

  • UPC: 610395592440
  • ASIN: B00BY9J8DG
  • Brand: Genteq
  • Manufacturer: GE/Genteq

Supco RCO810 3 n' 1 START Hard Start Kit

Supco RCO810 3 n' 1 START Hard Start Kit

This 3 in 1 start kit is for compressors with horse power of 1/12 through 1/5.

  • UPC: 759569276561
  • ASIN: B00A8O0E5Y
  • Brand: Supco
  • Size: Single Unit
  • Manufacturer: CE Sundberg